C016 00V000 000 1

C016 00V000 000 1

  • 厂商:

    AMPHENOL(安费诺)

  • 封装:

  • 描述:

    连接器 帽盖(盖),防护式 1 黑色

  • 数据手册
  • 价格&库存
C016 00V000 000 1 数据手册
Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors Series C 16-1/ C 16-3 The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence we offer our customers exceptional technical support and service in the areas of development, production and distribution. Amphenol-Tuchel Electronics GmbH has a successful history as a partner to our customers and sets standards for connector technology. Quality From the beginning of the development process, Amphenol-Tuchel Electronics GmbH gives quality considerations the top priority. Meeting customer requirements is the main focus of the product development process. Interdisciplinary project teams with diverse backgrounds from marketing, product engineering and production guarantee the development and production of robust and reliable connector solutions. Our quality accessment begins with the initial contact to the customer and extends through the life of the product. A satisfied customer is the measure of our success. Amphenol-Tuchel Electronics GmbH is ISO 9001, QS 9000 and VDA 6.1 certified. We strive to use environmentally friendly processes that minimize the waste of natural resources and introduction of toxins into the environment. Amphenol-Tuchel is an ISO 14001 certified company. General information We reserve the right to change the design due to improvement in quality, development or production requirements. With this release all former releases are no longer valid. This catalogue must not be used in any form or manner without our prior approval in writing (Copyright Law, Fair Trading Law, Civil Code). 2 Amphenol Content Page General information 2 Technical information 4 Remarks / Safety classification 7 Series C 16-1 Series C 16-3 View 8 Product description Order information Approvals 9 Characteristics 10 Derating curves Mounting instructions 11 Male cable connectors 12 Female receptacles 13 Female cable connectors 14 Male receptacles 15 Accessories 16 View 17 Product description Order information Approvals 18 Coding system 19 Characteristics 20 Derating curves 21 View of connector style 22 Mounting instruction 23 Shell size 1 Male cable connectors 24 Female receptacles Female cable connectors 25 Male receptacles Accessories 26 EMI versions 27 Shell size 2 Male cable connectors Female receptacles 30 Female cable connectors Male receptacles 31 Accessories 32 Crimp contacts pin 33 Crimp contacts socket 34 Part No. system for crimp contacts 35 Summary of Part Numbers 36 Amphenol 3 C 16-1 / C 16-3 Technical Information This comparison chart allows a cross reference between American Wire Gauge (AWG) and metric wire sizes (mm 2). Termination methods • Screw connection Screw clamps are designed acc. to EN 60999-1/VDE 06095.1. Chart 1 below shows the screw size depending on wire size and the required clamping and testing torque. Chart 2 AWG Wire composition Wire diameter Wire size 30 1 x 0,25 7 x 0,10 0,25 mm 0,36 mm 0,05 mm2 0,06 mm2 10 28 1 x 0,32 7 x 0,13 0,32 mm 0,38 mm 0,08 mm2 0,09 mm2 26 1 x 0,40 7 x 0,16 19 x 0,10 0,40 mm 0,48 mm 0,51 mm 0,13 mm2 0,14 mm2 0,15 mm2 24 1 x 0,51 7 x 0,20 19 x 0,13 0,51 mm 0,61 mm 0,64 mm 0,21 mm2 0,23 mm2 0,24 mm2 22 1 x 0,64 7 x 0,25 19 x 0,16 0,64 mm 0,76 mm 0,81 mm 0,33 mm2 0,36 mm2 0,38 mm2 20 1 x 0,81 7 x 0,32 19 x 0,20 0,81 mm 0,97 mm 1,02 mm 0,52 mm2 0,56 mm2 0,62 mm2 18 1 x 1,02 19 x 0,25 1,02 mm 1,27 mm 0,79 mm2 0,96 mm2 16 19 x 0,29 1,44 mm 1,23 mm2 14 19 x 0,36 1,80 mm 1,95 mm2 12 19 x 0,46 2,29 mm 3,09 mm2 10 37 x 0,40 3,10 mm 4,60 mm2 8 133 x 0,29 4,0 mm 8,80 mm2 6 133 x 0,36 5,5 mm 13,5 mm2 Chart 1 Wire size (mm2) 1 1,5 2,5 4 Screw size M 2,6 M 3 M3 M 3,5 M 4 M4 Test torque (Ncm) 40 50 80 120 50 6 120 Diagram 1 below shows the range of tensile strength for a screw connection with a clamp screw M3, fastened with a torque of 50 Ncm, depending on the wire size. Tensile strength Diagram 1 Wire gauge It has to be noted that wires of the same AWG number but with different composition have slightly different mm 2. Chart 3 Composition and Dimensions of Copper Wires Wire Size Wire Composition Wire diameter 0,09 mm 2 12 x 0,10 0,48 mm 0,14 mm2 18 x 0,10 0,50 mm 0,25 mm 14 x 0,15 0,70 mm 0,34 mm2 7 x 0,25 0,78 mm 0,5 mm 16 x 0,20 1,0 mm 0,75 mm2 24 x 0,20 1,2 mm 1,0 mm 2 32 x 0,20 1,4 mm 1,5 mm2 30 x 0,25 1,6 mm 2,5 mm 2 35 x 0,30 2,2 mm 4,0 mm2 56 x 0,30 2,8 mm 6,0 mm 19 x 0,64 3,4 mm 19 x 0,80 4,3 mm 10 mm 4 2 2 2 2 Amphenol C 16-1 / C 16-3 Technical Information • Crimp connection A crimp connection is a non-detachable electrical connection between a wire and a crimp contact produced with the crimp technology. Precise crimping dies which are matched to the crimp barrel and the wire size and a defined deformation result in a reliable electrical connection. There are open crimp barrels (stamped contacts) and closed crimp barrels (turned contacts). An important point of the quality of a crimp connection is the achieved tensile strength of the termination. Easily measured, the tensile strength is a practible means for quality control purposes. Diagram 2 below shows the required minimum tensile strength for open and closed barrels depending on the wire size. Assembly instructions For crimp contacts use the released crimp tool. The main advantages of crimp connections are: • Efficient termination of contacts. •Reproducible electrical and mechanical figures with a constant crimp quality. The insertion and extraction of crimp contacts shall only be approved with the corresponding insertion / extraction tool. A detailed description of the crimp technology can be found in our crimp tooling catalogs. The requirements for crimp connections are defined in IEC 60352 Part 2 / DIN EN 60352 Part 2. Diagram 2 N lb 1000 4000 3000 500 400 2000 300 1000 Min. tensile strength N / lb 200 500 400 100 300 50 40 200 30 100 20 50 40 10 30 5 mm 0,05 AWG 0,1 0,2 28 26 24 22 0,5 20 1,0 1,5 2,5 4,0 6,0 12 10 14 18 16 10,0 8 20 Wire gauge in mm / AWG Amphenol 5 C 16-1 / C 16-3 Technical Information Chart 5 Degree of protection Electrical devices to which connectors belong to have to be protected for safety reasons from outside influences like dust, foreign objects, direct contact, moisture and water. This protection is provided on industrial connectors by its housings with their latching devices and sealed cable entries. The degree of protection can be selected depending on the type of intended use. The standard IEC 60529 and/or DIN EN 60529/VDE 0470 Part 1 has specified the degree of protection and divided into several classes. The degree of protection is indicated in the following way: IP 65 Code letters (Internat. Protection) 1st charact. numeral (degree of protection against access to hazardous parts and against solid foreign objects) 2nd charact. numeral (degree of protection against ingress of water) The following charts 11 an 12 give an overview about all protection degrees. 2nd charact. Brief description numeral Definition 0 1 – Vertically falling drops shall have no harmful effects. Vertically falling drops shall have no harmful effects when the enclosure is tilted at any angel up to 15° on either side of the vertical. Water sprayed at an angle up to 60° on either side of the vertical shall have no harmful effects. Water splashed against the enclosure from any direction shall have no harmful effects. Water projected in jets against the enclosure from any direction shall have no harmful effects. Water projected in powerful jets against the enclosure from any direction shall have no harmful effects. Intrusion of water in quantities causing harmful effects shall not be possible when the enclosure is temporalily immersed in water for 30 min. in 1m depth. Intrusion of water in quantities causing harmful effects shall not be possible when the enclosure is continuously immersed in water under conditions which shall be agreed between manufacturer and user but which are more severe than for numeral 7. Water projected in powerful jets with high pressure against the enclosure from any direction shall have no harmful effects. 2 3 Protected against spraying water 4 Protected against splashing water 5 Protected against water jets 6 Protected against powerful water jets 7 Protected against the effects of temporary immersion in water 8 Protected against the effects of continous immersion in water 9 K 1) Protected against water during high pressure/steam jet cleaning Chart 4 1st charact. Brief description numeral Definition 0 1 – The probe, sphere of 50mm Ø, shall not fully penetrate and shall have adequate clearance from hazardous parts. The jointed test finger of 12mm Ø, 80mm length, shall have adequate clearance from hazardous parts. The probe, sphere of 12,5mm Ø, shall not fully penetrate. The probe of 2,5mm Ø shall not penetrate at all. 2 3 4 5 6 6 Non-protected Protected against access to hazardous parts with the back of a hand. Protected against solid foreign objects of ≥ 50mm Ø. Protected against access to hazardous parts with a finger. Protected against solid foreign objects of ≥12,5mm Ø. Protected against access to hazardous parts with a tool. Protected against solid foreign objects of ≥2,5mm Ø. Protected against access to hazardous parts with a wire. Protected against solid foreign objects of ≥1mm Ø. Protected against access to hazardous parts with a wire. Dust-protected. Protected against access to hazardous parts with a wire Dust-tight. Non-protected Protected against vertically falling water drops Protected against vertically falling water drops when enclosure tilted up to 15° The probe of 1mm Ø shall not penetrate at all. The probe of 1mm Ø shall not penetrate. Intrusion of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of the device or to impair safety. The probe of 1mm Ø shall not penetrate. No intrussion of dust. 1) Remark: Numeral acc. to DIN 40050 part 9, vehicles IP code Amphenol C 16-1/16-3 Remarks Safety classification 1. General Remarks These connectors are designed and produced in conformity with the low voltage directive (73/23/EWG) respectively Gerätesicherheitsgesetz (German law) and are especially in accordance with the standards DIN EN 61984 (VDE0627); IEC 60664-1 (VSE 0110-1) and IEC 60529. The connectors may be used only within the technical ratings. These connectors and/or plug and socket devices are designed and produced according to DIN EN 61984/VDE 0627. All technical data refer to mated connectors under live conditions. The safety of the connector system depends on the correct selection of products, proper assembly of the connector device, and a precise fit of the connectors. Connectors were completely mated according to their respective safety locking mechanism. Selection and testing of connectors and/or plug and socket devices to meet specific product or industrial requirements such as rated voltage and the related clearances and creepage distances are the responsibility of the user. 2. Application Remarks Connectors and/or plug and socket devices must be used according to specified technical ratings. The technical data represents the initial value of mated parts under predetermined conditions and length of time.These values could change with different test parameters or product requirements. The C 16-1/16-3 Series connectors are used in a wide variety of industries and equipment. Some of these include industrial machines and controls, data processing, instrumentation and test equipment, medical devices, telecommunication’s network and equipment, plus outdoor and marine applications. All rated data for the connectors listed in this catalog are based on overvoltage category III 1) and pollution degree 3 2) for electronic applications. 4. Termination Remarks Cable connectors are effectively secured when using the internal cable clamp. When the connector contains a simple gland bushing for retention without clamping ring the cable should have a strain relief close behind the connector. All cable properties or specifications must be compatible with the connector design and materials. Designated wire conductors must be terminated to the correct poles in the connector. Crimp contacts must be fully inserted into the plastic housing and retention assured with a slight tug on the wire. Wire should be stripped correctly according to printed specifications to insure no electrical contact can be made between the conductors. There should be no nicked or cut strains during the stripping action. 3. Assembling Remarks Protection against electrical shock of the termination of the connectors shall be secured by correct mounting. Connectors of the same or different series being mounted side by side may be protected against incorrect mating by the use of coding options. Care must be taken to ensure the parts are correctly mated and screws are tightened with the proper torque. 1) 2) 3) X X Female cable connector X X X Male receptacle screw / crimp X X X Female receptacle screw / crimp X X X Male receptacle solder X X X 3) Female receptacle solder X X X 3) X X X X 3) X 3) Cable clamp rewirable X connector with breaking capacity 1) finger safety mated enclosed mated Male cable connector hand back safety mated protective earthing contact X Style finger safety unmated enclosed unmated 5. Safety Classification acc. to DIN EN 61984 VDE 0627 with X X X X X X X X X X X X X X X X X X X 3) X X X X 3) X X X without Overvoltage category III: Equipment intended for the use in installations or parts of it in which lightning overvoltages do not need to be considered, however switching overvoltages generated by the equipment, and for cases where the reliability and the availability of the equipment or its dependent circuits are subject to special requirements. Examples are protecting means, switches and sockets. Pollution degree 3: Conductive pollution occurs or dry non-conductive pollution occurs which becomes conductive due to condensation which is to be expected. Protection against electrical shock on the termination side has to be secured by proper mounting. Amphenol 7 C 16-1 Product description The circular connectors of the C 16-1 series are designed to meet the high requirements of industrial applications under harsh environmental conditions. The range includes versions with screw, solder and crimp terminations. A selection of crimp contacts for hand crimp tools and crimp machines ensure a reliable termination resulting in qualitative, technical and economical advantages. A large selection of housing styles offers the user an optimal solution. 1) 8 Main features and advantages: •Circular connectors with contact arrangements 3 + PE and 6 + PE for power and signal applications •For applications in machine tools, measurement and control, process technology and medical equipment •Housing are made from high grade plastic material •Protected against unlocking by threaded coupling •Cable housing straight with PG 9, 11 and 13,5 cable outlet, Cable housing 90° with PG 9 and 11 cable outlet • Cable housing straight or right-angled with various cable outlets 1) • Protection degree IP 65/IP 67 per IEC 60529 in mated condition • Internal strain relief with screw clamp or clamping ring provides a safe cable restrain Other cable outlets uppon request Amphenol C 16-1 Product description Order information Approvals Order information Contact plating The standard plating is silver. Gold plated contacts are available upon request. Min order quantity = 100 contacts per type. Color coding Upon request the coupling ring of the plugs and the housings of the receptacles can be delivered in the colors red, green, blue, yellow and grey. Min order quantity = 250 pcs. per type. Crimp version Order numbers do not include crimp contacts. Please order separately (see page 33/34). Crimp contact for higher currents are available upon request. Crimp tooling Ask for our catalog ”Tools“ Mechanical coding Achieved with special coding pins which are inserted into contact cavities. Min. order quantity = 250 pcs. per type. Testhouse Characteristis Approval No. VDE 3+PE, 400 V, 16 A 6+PE, 250 V, 10 A 1781 1780 SEV 3+PE, 400 V, 16 A 6+PE, 250 V, 6 A 00.0394 UL 3+PE, 250 V, 12 A 6+PE, 250 V, 8 A E 63093 CSA 3+PE, 250 V, 12 A 6+PE, 250 V, 8 A 6+PE, 250 V, 15 A 48932 German LLyod 3+PE, 250 V, 16 A 6+PE, 50 V, 8 A 14108 / 84 In general approvals refer to representative versions of the connector series. Extail and specifications of test upon request. Amphenol 9 C 16-1 Characteristics General Characteristics Characteristics Standard Number of contacts 3 + PE Electrical Characteristics 6 + PE screw type solder type crimp type 400 V 250 V 200 V Rated insulation voltage IEC 60664-1 1) Rated impulse withstand voltage IEC 60664-1 1) 6000 V 4000 V Pollution degree IEC 60664-1 1) 3 3 Installation (overvoltage) category IEC 60664-1 1) III III Material group IEC 60664-1 1) II II Current carrying capacity IEC 60512-5-2, Test 5b 10 A / + 55 °C 16 A / + 55 °C 13 A / + 55 °C Insulation resistance IEC 60512-3-1 ≥ 10 Ω ≥ 10 Ω Contact resistance IEC 60512-2-1 ≤5mΩ ≤5mΩ 8 8 Climatical Characteristics Climatic category IEC 60068-1 40 / 100 / 56 Operating temperature 40 / 125 / 56 -40°C ... +100°C Mechanical Characteristics IP-degree of protection IEC 60529 Insertion and withdrawal force IEC 60512-13-2, Test 13b Mechanical operation IEC 60512-9-1, Test 9a IP 65 / IP 67 ≤ 15 N ≤ 30 N ≥ 500 mating cycles Materials Housing material Polyamid 6.6 Dielectric material Polyamid 6.6 Gasket material Neoprene Contact plating silver plated / gold plated Other Characteristics Termination technique schrauben löten crimpen Wire gauge mm2 / AWG max. 2,5 mm2 0,75 mm2 0,14 - 1,5 mm2 Flammability UL 94 round thread DIN 405 Locking system Fire protection 1) VO DIN 5510 Part 2 DIN 53438 Part 1-3 S1 IEC 60664-1 =^ VDE 0110-1 =^ DIN EN 60664-1 The stated technical values refer to the use as connector. If these components are used as plug and socket device a reduced current carrying capacity has to be considered. 10 Amphenol C 16-1 Derating curves No of contacts 6 + PE y No of contacts 3 + PE alle Ansc 24 22 20 18 16 14 12 10 8 6 4 2 Current carrying capacity y g p Current carrying capacity A all c wire °C 0 10 20 30 40 50 60 70 80 90100 BaAmbient elementetemperature Umgeb ngstemperat r A 24 22 20 18 16 14 12 10 8 6 4 2 alle Ko all cont a) Ansc wire b) Ansc wire a b 0 10 20 30 40 50 60 70 80 90100 110120 B l Ambient t U temperature b t t all contacts wire gauge 2,5 mm2, 14 AWG °C all contacts a) wire gauge 1,5 mm2, 16 AWG b) wire gauge 0,75 mm2, 20 AWG C 16-1 Shinning lengths Screw contacts Solder contacts Crimp contacts 0,14 - 0,50 mm2 0,50 - 2,50 mm2 Mounting instructions 1) Torque for back shell and cable clamp min. 1Nm max. 2Nm end splice recommended clamping ring sealing gasket coupling ring male internal strain relief 7,0+1 mm 1) 4,0+1 mm 3+0,5 mm 3,5 +1 mm Torque for back shell and cable clamp cable min. 1Nm back shell nut max. 2Nm right angled coupling ring male sealing gasket back shell metal washer clamping ring cable nut female female Amphenol Amphenol C 16-1 Amphenol C 16-1 11 C 16-1 Male cable connectors Description Male cable connector, 3+PE screw, 6+PE solder termination, with cable clamp or clamping ring Drawing Part. no. Cable outlet No. of cont. 3 + PE Ø 8-10 Ø 10-12 Ø 10-12 T 3108 001 T 3108 101 T 3108 200 (with clamping ring) 6 + PE T 3104 001 T 3104 101 T 3104 200 (with clamping ring) Male cable connector, 3+PE screw, 6+PE solder termination, without cable clamp Male cable connector, crimp version without contacts 1), with cable clamp or clamping ring Male cable connector, right-angled, 3+PE screw, 6+PE solder termination, with clamping ring Male cable connector, right-angled, crimp version, without contacts 1), with clamping ring 1) 3 + PE T 3108 000 T 3108 100 – 6 + PE T 3104 000 T 3104 100 – 6 + PE T 3104 501 T 3104 601 T 3104 701 (with clamping ring) Ø 6-8 Cable outlet Ø 8-10 3 + PE T 3108 081 T 3108 091 – 6 + PE T 3104 081 T 3104 091 – 6 + PE T 3104 581 T 3104 591 – Please order crimp contacts separatly, see page 33/34, part numbersystem for crimpcontacts see page 35. 12 Amphenol C 16-1 Female receptacles Panel cutout 2) Description 1) 2) Drawing No. of cont. Part. no. Female receptacle, screw termination 3 + PE T 3111 000 Female receptacle, solder termination 6 + PE T 3107 000 Female receptacle, crimp version, without contacts 1) 6 + PE T 3107 500 Please order crimp contacts separatly, see page 33/34, past numbersystem for crimpcontacts see page 35. Mounting hole Ø 22 without chamfer, suitable sealing for screws is necessary. Amphenol 13 C 16-1 Female cable connectors Description Female cable connector, 3+PE screw, 6+PE solder termination, with cable clamp or claming ring Drawing No. of cont. 3 + PE Part No. Cable outlet Ø 8-10 Ø 10-12 Ø 10-12 T 3109 001 T 3109 101 T 3109 200 (with clamping ring) 6 + PE T 3105 001 T 3105 101 T 3105 200 (with clamping ring) Female cable connector, 3+PE screw, 6+PE solder termination, without cable clamp Female cable connector, crimp version without contacts 1), with cable clamp or claming ring Female cable connector, right-angled, 3+PE screw, 6+PE solder termination, with clamping ring Female cable connector, right-angled, crimp version, without contacts 1), with clamping ring 1) 3 + PE T 3109 000 T 3109 100 – 6 + PE T 3105 000 T 3105 100 – 6 + PE T 3105 501 T 3105 601 T 3105 701 (with clampin ring) Ø 6-8 Cable outlet Ø 8-10 3 + PE T 3109 081 T 3109 091 – 6 + PE T 3105 081 T 3105 091 – 6 + PE T 3105 581 T 3105 591 – Please order crimp contacts separatly, see page 33/34, part numbersystem for crimpcontacts see page 35. 14 Amphenol C 16-1 Male receptacles Panel cutout 2) Description Drawing No. of cont. Part No. Male receptacle, screw termination 3 + PE T 3110 000 Male receptacle, solder termination 6 + PE T 3106 000 Male receptacle, crimp version, without contacts 1) 6 + PE T 3106 500 Male receptacle, straight dip solder pins 3 + PE T 3110 010 Hole pattern on PCB Male receptacle, straight dip soldier pins 6 + PE T 3106 010 Hole pattern on PCB Please order crimp contacts separatly, see page 33/34, past numbersystem for crimpcontacts see page 35. Mounting hole Ø 22 without chamfer, suitable sealing for screws is necessary. Amphenol 1) 2) 15 C 16-1 Accessories Figure for male connector 25,5 Ø 29,0 T 6482 200 60,0 Ø 29,0 Ø 29,0 Back shell, straight version, with clamping ring, Packaging unit 10 pcs. for male receptacle 25,5 for female cable connector 31,3 ca. 135 Backshell, straight version, packaging unit 10 pcs. Part No. T 6482 201 ca. 135 Protective cover for female cable connector and female receptacle Figure for female receptacle 31,3 Ø 29,0 Protective cover for male cable connector and male receptacle Part No. T 6483 201 T 6483 200 60,0 Description cable outlet 8 -10 / 0,315 - 0,394 cable outlet 10 -12 / 0,394 - 0,472 T 3102 003 7 X T 3102 004 7 X cable outlet 10 -12 / 0,394 - 0,472 T 3102 005 7 X Backshell, right-angled with clamping ring, packaging unit 10 pcs. Cable clamp, packaging unit 10 pcs. cable outlet 8 -10 / 0,315 - 0,394 cable outlet 10 -12 / 0,394 - 0,472 T 3102 015 7 X T 3102 014 7 X cable clamp diameter Ø 6 -12 N 16 110 2000 X 16 Amphenol C 16-3 Product description The circular connector series C 16-3 has two housing sizes. The connectors are designed to meet the high requirements of industrial applications under harsh environmental conditions. The range includes versions with screw and crimp terminations. A selection of crimp contacts for hand crimp tools and crimp machines enables a reliable termination resulting in qualitative, technical and economical advantages. A broad selection of housing styles are available. Amphenol Main features and advantages: • Circular connectors for power and signal applications with following contact arrangements: Shell size 1: 8 + PE, 14 + PE, 17 + PE Shell size 2: 5 + PE, 12 + PE, 14 + PE, 19 + PE • For applications in machine tools, measurement and control, process technology and medical equipment • Housing are made from high grade plastic material. • Vibration safe connection by solid bayonet coupling with lock in position. • Cable housing straight or right-angled with various cable outlets • Protection degree IP 65 in mated position. • Internal cable clamp or clamping ring provides a safe cable restrain. 17 C 16-3 Product description Order information Approvals Order information Color coding Upon request the coupling ring of the plugs and the housings of the receptacles can be delivered in the color red, green, blue, yellow and grey. Polarization Depending on the contact arrangements the polarization of this connector series can be varied. The contact inserts can be mounted in alternate positions. The order number in the catalog refers always to position 1. The position of the contact inserts can also be changed by the customer using a disassembly tool (see page 26 and 29) to remove the insert and remount it in the required position (see page 19). Testhouse Approvals Crimp version Order numbers do not include crimp contacts. Please order separately (page 33/34). Crimp contacts for higher currents are available upon request. Crimp tooling Ask for our crimp tooling catalogs. Approval No. VDE 3964 UL E 63093 CSA 49932-9 In general approvals refer to representative versions of the connector series. Extail and specifications of test upon request. 18 Amphenol C 16-3 Coding system Polarization Depending on the contact arrangements the polarization of this connector series can be varied. Please take care of the housing and contact insert characteristics. Shell size 1 Shell size 2 No of contacts No of coding possibil. Position No of contacts No of coding possibil. Position 8 + PE 4 1, 3, 5, 7 5 + PE 6 1, 2, 3, 4, 6, 7 14 + PE 7 1, 2, 3, 4, 5, 6, 7 14 + PE 7 1, 2, 3, 4, 5, 6, 7 17 + PE 6 1, 2, 3, 4, 5, 7 12 + PE 7 1, 2, 3, 4, 5, 6, 7 19 + PE 6 1, 3, 4, 5, 6, 7 Coding point on the shell Coding point on the contact insert Pos. 1 Pos. 2 Pos. 3 Pos. 5 Pos. 6 Pos. 7 Pos. 1 Pos. 2 Pos. 3 Pos. 5 Pos. 6 Pos. 7 Pos. 4 Pin contact insert termination side Pos. 4 Socket contact insert termination side Disassembly of contact inserts with disassembly tool (see page 26 und 29) Pin or socket contact insert Disassembly tool Amphenol 19 C 16-3 Characteristics General Characteristics Standard Characteristics Shell size 1 Number of contacts Shell size 2 8 + PE 14 + PE 17 + PE 5 + PE 12 + PE 14 + PE 19 + PE Electrical Characteristics Rated insulation voltage IEC 60664-1 1) 400 V 100 V 100 V 400 V 3 x 500 V 9 x 300 V 400 V 250 V Rated impulse withstand voltage IEC 60664-1 1) 6000 V 3000 V 3000 V 6000 V 3 x 6000 V 9 x 4000 V 3110 V 4000 V Pollution degree IEC 60664-1 1) 3 3 3 3 3 3 3 Installation (overvoltage) category IEC 60664-1 1) III III III III III III III Material group IEC 60664-1 1) II II II II II II II Current carrying capacity IEC 60512-5-2, Test 5b IEC 60512-3-1, Test 3a IEC 60512-2-1, Test 2a 12 A 11 x 6 A 4 x 16 A 6A 21 A 3 x 21 A 9 x 11 A 4x6A 11 x 12 A 6A Insulation resistance Contact resistance ≥ 10 8 Ω ≤ 5 mΩ Climatical Characteristics Climatic category 40 / 125 / 56 IEC 60081-1 Operating temperature 40 / 100 / 56 40 / 125 / 56 -40°C ... +125°C (5+PE: +100°C) Mechanical Characteristics IP-degree of protection IEC 60529 Insertion and withdrawal force IEC 60512-13-2, Test 13b IEC 60512-9-1, Test 9a Mechanical operation IP 65 ≤ 25 N ≤ 30 N ≤ 22 N ≤ 15 N ≤ 25 N ≤ 30 N ≤ 25 N ≥ 500 mating cycles Materials Housing material Polyamid 6.6 Dielectric material Polyamid 6.6 Gasket material Neoprene Contact plating silver plated / gold plated Other Characteristics crimp Termination technique Wire range mm / AWG 2 Flammability 0,14 1,5 mm2 UL 94 20 0,14 1,0 mm2 4 mm2 crimp 0,14 2,5 mm2 0,14 2,5 mm2 0,14 1,0 mm2 VO bayonet Locking system Fire protection 0,14 2,5 mm2 screw DIN 5510 Part 2 DIN 53438 Part 1-3 S1 1) IEC 60664-1 =^ VDE 0110-1 =^ DIN EN 60664-1 The stated technical values refer to the use as connector. If these components are used as plug and socket device a reduced current carrying capacity has to be considered. Amphenol C 16-3 Derating curves Shell size 1 8+PE 8+PE a)a)alle all Kcontacts Ø 1,6 Ansch wire gauge 16 AWG all con wire g 15 14 12 10 8 6 4 2 0 10 20 30 40 50 60 70 80 90 100 110 120 Ambient temperature Current carrying capacity A °C 14+PE 14+PE a)a)4 4Kon contacts Ø 2,5 wire gauge 16 AWG Ansch b)4 11 concontacts Ø 1,5 wireg gauge 20 AWG wire b) 11 Ko Ansch 11 con wire g a 20 15 10 b 5 0 10 20 30 40 50 60 70 80 90 100 110 120 Ambient temperature °C 17+PE 17+PE all Kontak contacts Ø 1,5 alle wire gauge 20 AWG Anschlußq all contact wire gauge 10 9 8 7 6 5 4 3 2 1 0 A Current carrying capacity Current carrying capacity A 10 20 30 40 50 60 70 80 90 100 110 120 °C Ambient temperature Shell size 2 5+PE 5+PE all Ko contacts Ø 2,5 a)a)alle wire gauge 12 AWG Ansch b)allallcon contacts Ø 2,5 wireg gauge 14 AWG wire 0 b) alle Ko Ansch all con wire g 10 20 30 40 50 60 70 80 90 100 110 120 A Current carrying capacity Current carrying capacity A 36 33 30 27 24 21 18 15 12 9 6 3 °C 30 25 20 15 5 0 15 10 a b 5 0 10 20 30 40 50 60 70 80 90 100 110 120 Ambient temperature Amphenol 10 20 30 40 50 60 70 80 90 100 110 120 Ambient temperature 14+PE 14+PE a)a)1111Kocontacts Ø 1,6 wire gauge 16 AWG Ansc b)114co contacts Ø 1,5 wireg gauge 20 AWG wire b) 4 Ko Ansc 4 con wire g °C A Current carrying capacity Current carrying capacity 20 b 10 Ambient temperature A a °C 19+PE 19+PE all Kon contacts Ø 1,5 alle wire gauge 20 AWG Anschlu all conta wire gau 12 11 10 9 8 7 6 5 4 3 2 1 0 12+PE 12+PE a)a)3 3Kocontacts Ø 2,5 wire gauge 14 AWG Ansc b)3 con 9 contacts Ø 1,6 wire wire gauge 16 AWG b) 9 Ko Ansc 9 con wire 10 20 30 40 50 60 70 80 90 100 110 120 Ambient temperature °C 21 C 16-3 View of connector style, Shell size 1 and 2 Identification Male cable connector Figure Description Long version with internal cable clamp Conn. Style Page Size 1 Size 2 24 30 24 30 24 30 25 31 25 31 25 31 25 30 25 – 26 31 I Short version, with clamping ring H Right-angled, with clamping ring Female cable connector Long version with internal cable clamp Short version, with clamping ring K E D Right-angled, with clamping ring F Female receptacle Flange mounting, with mounted gasket G Panel mounting with ring nut, with gasket Male receptacle N Flange mounting, with mounted gasket C 22 Amphenol C 16-3 Mounting instruction Torque for back shell and cable screw min. 1 Nm max. 2 Nm clamping ring cable nut short back shell sealing gasket long back shell metal washer internal strain relief coupling ring male right-angled Amphenol C 16-3 female Shinning lengths Screw contacts Solder contacts Crimp contacts 0,14 - 0,50 mm2 0,50 - 2,50 mm2 1) 7,0+1 mm 1) 4,0+1 mm 3+0,5 mm 3,5 +1 mm end splice recommended Amphenol 23 C 16-3 Shell size 1 Male cable connectors I Description H Drawing K No. of cont. Contacts 2) Part No. Cable outlet Ø 10 -12 Male cable connector, long, style I with internal cable clamp, without contacts 1) Ø 12 -14 8 + PE .N 01 016 00... C016 10I008 002 1 C016 10I008 003 1 14 + PE 11 x C016 10I014 002 1 C016 10I014 003 1 .N 01 015 00... 4x .N 01 025 00... 17 + PE .N 01 015 00... C016 10I017 002 1 C016 10I017 003 1 Cable outlet Ø 8 -10 Ø 10 -12 8 + PE .N 01 016 00... C016 10H008 002 1 C016 10H008 003 1 Male cable connector, short, style H with clamping ring, without contacts 1) 14 + PE 11 x C016 10H014 002 1 C016 10H014 003 1 .N 01 015 00... 4x .N 01 025 00... 17 + PE .N 01 015 00... C016 10H017 002 1 C016 10H07 003 1 Male cable connector, style K with clamping ring, without contacts 1) 8 + PE .N 01 016 00... C016 10K008 002 1 C016 10K008 003 1 14 + PE 11 x C016 10K014 002 1 C016 10K014 003 1 .N 01 015 00... 4x .N 01 025 00... 17 + PE .N 01 015 00... C016 10K017 002 1 C016 10K017 003 1 1) Please order crimp contacts separatly, see page 33/34. 24 2) Part No system for crimp contacts, see page 35. Amphenol C 16-3 30,2 +0,2 (1.189) 28,6 ±0,1 (1.126) 3,8 +0,1 (.15) Shell size 1 Female receptacles 26,2 +0,2 (1.031) oder M3,5 28,6 ±0,1 (1.126) Panel cutout G Identification SW27,2 +0,2 (1.071) Panel cutout N No. of cont. Contacts 2) Drawing Female receptacle, without contacts 1) Female receptacle, style N, without contacts 1) Part No. 8 + PE .N 02 016 00… C016 10G008 000 1 14 + PE 11 x .N 02 015 00... 4 x .N 02 025 00… C016 10G014 000 1 17 + PE .N 02 015 00... C016 10G017 000 1 8 + PE .N 02 016 00… C016 10N008 006 1 14 + PE 11 x .N 02 015 00... 4 x .N 02 025 00… C016 10N014 006 1 17 + PE .N 02 015 00... C016 10N017 006 1 C 16-3 Shell size 1 Female cable connectors E Identification D Drawing F No. of cont. Female cable connector, long, style E with internal cable clamp, without contacts 1) 8 + PE Contacts 2) Part No. Cable outlet Ø 10-12 Ø 12-14 .N 02 016 00… C016 10E008 002 1 C016 10E008 003 1 14 + PE 11 x .N 02 015 00... C016 10E014 002 1 C016 10E014 003 1 4 x .N 02 025 00… 17 + PE .N 02 015 00... C016 10E017 002 1 C016 10E017 003 1 Ø 8-10 Female cable connector, short, style D with clamping ring, without contacts 1) Cable outlet Ø 10-12 8 + PE .N 02 016 00… C016 10D008 002 1 C016 10D008 003 1 14 + PE 11 x .N 02 015 00... C016 10D014 002 1 C016 10D014 003 1 4 x .N 02 025 00… 17 + PE .N 02 015 00... C016 10D017 002 1 C016 10D017 003 1 Female cable connector, style F with clamping ring, without contacts 1) 8 + PE .N 02 016 00… C016 10F008 002 1 C016 10F008 003 1 14 + PE 11 x .N 02 015 00... C016 10F014 002 1 C016 10F014 003 1 4 x .N 02 025 00… 17 + PE .N 02 015 0005 C016 10F017 002 1 C016 10F017 003 1 1) Please order crimp contacts separatly, see page 33/34. Amphenol 2) Part No system for crimp contacts, see page 35. 25 C 16-3 Shell size 1 Male receptacles C Identification Panel cutout Drawing No. of cont. Male receptacle, style C, without contacts 1) Contacts 2) Part No. 8 + PE .N 01 016 00… C016 10C008 000 1 14 + PE 11 x .N 01 015 00... 4x .N 01 025 00… C016 10C014 000 1 17 + PE .N 01 015 00... C016 10C017 000 1 C 16-3 Shell size 1 Accessories Identification Drawing Part No. Protective cover for male cable connector and male receptacle. for male cable connector C016 00U000 000 1 for female cable connector Protective cover for female cable connector and female receptacle. C016 00V000 000 1 Disassembly tool for pin-and socket inserts 1) Please order crimp contacts separatly, see page 33/34. 26 for male receptacle C016 00U000 020 1 for female receptacle C016 00V000 020 1 FH 0000-016 2) Part No system for crimp contacts, see page 35. Amphenol C 16-3 EMI Shell size 1 shielded version The C 16-3 EMI connectors excel by versatile fields of application, especially high mechanical requirements, industrial ebvironments and demands for safe contact. Main features: • high attenuation of shielding • contact inserts suitable for standard and EMI versions • completely compatible with standard C 16-3, size 1 • same technical characteristics as standard C 16-3 Two versions available: 1. Version with metalized plastic housing accord. VDE 0610. PE wire is connected to cable shield and housing. In case of error the current will be lead directly to the PE wire. 2. Combined version with metalized plastic and two-part metal housing accord. VDE 0113. PE wire is securely and firmly connected with the metal housing. Crimp version Order numbers do not include crimp contacts. Please order separately (see page 33/34). Crimp contact for higher currents are available upon request. Crimp tooling Ask for our catalog ”Tools“. Amphenol 27 C 16-3 Shell size 1 C 16-3 EMI Description Drawing No. of cont. Contacts2) Part No. Cable outlet Ø 10-12 Male cable connector, style H, without contacts 1), without cable screw, metalized plastic housing Ø 12 -14 8 + PE .N 01 016 00... C016 10H008 012 5 C016 10H008 013 5 14 + PE 11 x C016 10H014 012 5 C016 10H014 013 5 .N 01 015 00... 4x .N 01 025 00... 17 + PE .N 01 015 00... C016 10H017 012 5 C016 10H017 013 5 Female cable connector, style D, without contacts 1), without cable screw, metalized plastic housing 8 + PE .N 01 016 00... C016 10D008 012 5 C016 10D008 013 5 14 + PE 11 x C016 10D014 012 5 C016 10D014 013 5 .N 01 015 00... 4x .N 01 025 00... 17 + PE .N 01 015 00... C016 10D017 012 5 C016 10D017 013 5 Cable outlet Ø 9-11 Male cable connector, without contacts 1), two part metal housing, with PE contact 8 + PE .N 01 016 00... C016 10H008 801 3 14 + PE 11 x C016 10H014 801 3 .N 01 015 00... 4x .N 01 025 00... Female cable connector, without contacts 1), two part metal housing, with PE contact 17 + PE .N 01 015 00... C016 10H017 801 3 8 + PE .N 01 016 00... C016 10D008 801 3 14 + PE 11 x C016 10D014 801 3 .N 01 015 00... 4x .N 01 025 00... 17 + PE .N 01 015 00... 1) Please order crimp contacts separatly, see page 33/34. 28 2) C016 10D017 801 3 Part No system for crimp contacts, see page 35. Amphenol C 16-3 3,8 +0,1 (.15) SW27,2 +0,2 (1.071) Panel cutout Description 30,2 +0,2 (1.189) 26,2 +0,2 (1.031) oder M3,5 Shell size 1 C 16-3 EMV 28,6 ±0,1 (1.126) 28,6 ±0,1 (1.126) Drawing No. of cont. Female receptacle, style G, without contacts 1) Female receptacle, style N, without contacts 1) Male receptacle, style C, without contacts 1) Panel cutout Contacts 2) Part No. 8 + PE .N 01 016 00… C016 10G008 000 5 14 + PE 11 x.N 01 015 00... 4 x.N 01 025 00… C016 10G014 000 5 17 + PE .N 01 015 00... C016 10G017 000 5 8 + PE .N 01 016 00… C016 10N008 000 5 14 + PE 11 x.N 01 015 00... 4 x.N 01 025 00… C016 10N014 000 5 17 + PE .N 01 015 00... C016 10N017 000 5 8 + PE .N 01 016 00… C016 10C008 000 5 14 + PE 11 x.N 01 015 00... 4 x.N 01 025 00… C016 10C014 000 5 17 + PE .N 01 015 00... C016 10C017 000 5 Mounting instruction 70 3 16 30 65 30 4 60 min.4 Amphenol 29 C 16-3 Shell size 2 Male cable connectors I Description Drawing H K No. of cont. Contacts 2) Ø 12-14 Male cable connector, long, style I with internal cable clamp, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) 5 + PE – 12 + PE 9 x .N 01 016 00… C016 10I012 003 2 C016 10I012 004 2 C016 10I012 005 2 4 x .N 01 025 00… 14 + PE 4 x .N 01 015 00… C016 10I014 003 2 C016 10I014 004 2 C016 10I014 005 2 11 x .N 01 016 00… 19 + PE .N 01 015 000... C016 10I019 003 2 C016 10I019 004 2 C016 10I019 005 2 – 5 + PE Male cable connector, style K with clamping ring, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) Ø 19-21 C016 20I005 103 2 C016 20I005 104 2 C016 20I005 105 2 Ø 10-12 Male cable connector, short, style H with clamping ring, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) Part No. Cable outlet Ø 14-16 Cable outlet Ø 12-14 Ø 14-18 C016 20H005 103 2 C016 20H005 104 2 – 12 + PE 9 x .N 01 016 00… C016 10H012 003 2 C016 10H012 004 2 4 x .N 01 025 00… – 14 + PE 4 x .N 01 015 00… C016 10H014 003 2 C016 10H014 004 2 C016 10H014 005 2 11 x .N 010 1600… 19 + PE .N 01 015 00... 5 + PE – C016 10H019 003 2 C016 10H019 004 2 – – C016 20K005 104 2 – 12 + PE 9 x .N 01 016 00… 4 x .N 01 025 00… – C016 10K012 004 2 – 14 + PE 4 x .N 01 015 00… 11 x .N 01 016 00… – C016 10K014 004 2 – 19 + PE .N 01 015 00... – C016 10K019 004 2 – C 16-3 Shell size 2 Female receptacle G Identification Drawing No. of cont. Female receptacle, style G, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) 1) Please order crimp contacts separatly, see page 33/34. 30 Panel cutout 5 + PE 2) Contacts 2) – Part No. C016 20G005 100 2 12 + PE 9 x .N 02 016 00… 4 x .N 02 025 00… C016 10G012 000 2 14 + PE 4 x .N 02 015 00… 11 x .N 02 016 00… C016 10G014 000 2 19 + PE .N 02 015 00... C016 10G019 000 2 Part No system for crimp contacts, see page 35. Amphenol C 16-3 Shell size 2 Female cable connectors E Description D Drawing F No. of cont. Contacts 2) Ø 12-14 Female cable connector, long, style E with internal cable clamp, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) 5 + PE – Part No. Cable outlet Ø 14-16 Ø 19-21 C016 20E005 103 2 C016 20E005 104 2 C016 20E005 105 2 12 + PE 9 x .N 02 016 00… C016 10E012 003 2 C016 10E012 004 2 C016 10E012 005 2 4 x .N 02 025 00… 14 + PE 4 x .N 02 015 00… C016 10E014 003 2 C016 10E014 004 2 C016 10E014 005 2 11 x .N 02 016 00… 19 + PE .N 02 015 00... C016 10E019 003 2 C016 10E019 004 2 C016 10E019 005 2 Cable outlet Ø 10-12 Ø 12-14 Female cable connector, short, style D with clamping ring, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) 5 + PE Female cable connector, style F with clamping ring, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) – C016 20D005 103 2 C016 20D005 104 2 – 12 + PE 9 x .N 02 016 00… C016 10D012 003 2 C016 10D012 004 2 4 x .N 02 025 00… – 14 + PE 4 x .N 02 015 00… C016 10D014 003 2 C016 10D014 004 2 11 x .N 02 016 00… – 19 + PE .N 01 015 00... C016 10D019 003 2 C016 10D019 004 2 – 5 + PE – – C016 20F005 104 2 – 12 + PE 9 x .N 02 016 00… 4 x .N 02 025 00… – C016 10F012 004 2 – 14 + PE 4 x .N 02 015 00… – C016 10F014 004 2 – 19 + PE .N 02 015 00... – C016 10F019 004 2 – C 16-3 Shell size 2 Male receptacle Panel cutout C Description Drawing No. of cont. Male receptacle, style C, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) 1) Please order crimp contacts separatly, see page 33/34. Amphenol 2) Contacts 2) Part No. 5 + PE – C016 20C005 100 2 12 + PE 9 x .N 01 016 00… 4 x .N 01 015 00... C016 10C012 000 2 14 + PE 4 x .N 01 015 00… 11 x .N 01 016 00… C016 10C014 000 2 19 + PE .N 01 015 00... C016 10C019 000 2 Part No system for crimp contacts, see page 35. 31 C 16-3 Shell size 2 Accessories Description Protective cover for male cable connector and male receptacle Protective cover for female cable connector and female receptacle Disassembly tool for pin-and socket inserts 32 Figure Part No. for male cable connector for male receptacle C016 00U000 010 2 C016 00U000 000 2 for female cable connector for female receptacle C016 00V000 010 2 C016 00V000 000 2 FH 0002-016 Amphenol C 16-1 und 16-3 Stamped single contacts Stamped contacts on reel for hand crimping tools Crimp contacts Pin Series C 16-1 C 16-1 C 16-3 C 16-3 C 16-3 C 16-3 C 16-3 C 16-3 Contact Ø in mm 1,6 1,6 1,5 1,5 1,6 1,6 1,6 2,5 Stamped contacts on reel for crimp machines 200 pcs Insulation No. of cont. Ø in mm 1,0 - 2,0 1,8 - 2,8 1,6 - 2,3 1,8 - 2,0 1,0 - 2,0 1,8 - 2,8 2,5 - 3,5 1,8 - 2,8 2,5 - 3,5 6 + PE 6 + PE Shell size – – 2000 pcs (feeding left or right hand side) Part No. Wire gauge in mm2 AWG Supplied as 0,14 - 0,5 single contact 100 VN 01 016 0011 (1) VN 01 016 0011 (2) 26 - 20 contacts on reel 200 ZN 01 016 0011 (1) ZN 01 016 0011 (2) right 2000 HN 01 016 0011 (1) HN 01 016 0011 (2) left 2000 TN 01 016 0011 (1) TN 01 016 0011 (2) pcs. Contact plating silver gold 0,5 - 1,5 single contact 100 VN 01 016 0004 (1) VN 01 016 0004 (2) 20 - 16 contacts on reel 200 ZN 01 016 0004 (1) ZN 01 016 0004 (2) right 2000 HN 01 016 0004 (1) HN 01 016 0004 (2) left 2000 TN 01 016 0004 (1) TN 01 016 0004 (2) 14 + PE 1 0,14 - 0,5 single contact 100 VN 01 015 0046 (1) VN 01 015 0046 (2) 17 + PE 1 26 - 20 contacts on reel 200 ZN 01 015 0046 (1) ZN 01 015 0046 (2) 14 + PE 2 right 2000 HN 01 015 0046 (1) HN 01 015 0046 (2) 19 + PE 2 left 2000 TN 01 015 0046 (1) TN 01 015 0046 (2) 14 + PE 1 0,5 - 1,0 single contact 100 VN 01 015 0047 (1) VN 01 015 0047 (2) 17 + PE 1 20 - 18 contacts on reel 200 ZN 01 015 0047 (1) ZN 01 015 0047 (2) 14 + PE 2 right 2000 HN 01 015 0047 (1) HN 01 015 0047 (2) 19 + PE 2 left 2000 TN 01 015 0047 (1) TN 01 015 0047 (2) 8 + PE 1 0,14 - 0,5 single contact 100 VN 01 016 0003 (1) VN 01 016 0003 (2) 12 + PE 2 26 - 20 contacts on reel 14 + PE 2 200 ZN 01 016 0003 (1) ZN 01 016 0003 (2) right 2000 HN 01 016 0003 (1) HN 01 016 0003 (2) left 2000 TN 01 016 0003 (1) TN 01 016 0003 (2) 8 + PE 1 0,5 - 1,5 single contact 100 VN 01 016 0002 (1) VN 01 016 0002 (2) 12 + PE 2 20 - 16 contacts on reel 200 ZN 01 016 0002 (1) ZN 01 016 0002 (2) 14 + PE 2 right 2000 HN 01 016 0002 (1) HN 01 016 0002 (2) left 2000 TN 01 016 0002 (1) TN 01 016 0002 (2) 8 + PE 1 1,5 - 2,5 single contact 100 VN 01 016 0005 (1) VN 01 016 0005 (2) 12 + PE 2 16 - 14 contacts on reel 200 ZN 01 016 0005 (1) ZN 01 016 0005 (2) 14 + PE 2 right 2000 HN 01 016 0005 (1) HN 01 016 0005 (2) left 2000 TN 01 016 0005 (1) TN 01 016 0005 (2) 14 + PE 1 0,5 - 1,5 single contact 100 VN 01 025 0001 (101) VN 01 025 0001 (102) 12 + PE 2 20 - 16 contacts on reel 200 ZN 01 025 0001 (1) ZN 01 025 0001 (2) right 2000 HN 01 025 0001 (1) HN 01 025 0001 (2) left 2000 TN 01 025 0001 (1) TN 01 025 0001 (2) 14 + PE 1 1,5 - 2,5 single contact 100 VN 01 025 0010 (101) VN 01 025 0010 (102) 12 + PE 2 16 - 14 contacts on reel 200 ZN 01 025 0010 (1) ZN 01 025 0010 (2) right 2000 HN 01 025 0010 (1) HN 01 025 0010 (2) left 2000 TN 01 025 0010 (1) TN 01 025 0010 (2) Single contact in plasticbag stamped contact on red – HN = feeding right side / TN = feeding left side Amphenol 33 C 16-1 und 16-3 Stamped single contacts Stamped contacts on reel for hand crimping tools Crimp contacts Socket Series C 16-3 C 16-3 C 16-1 Contact Ø in mm 1,5 1,5 1,6 200 pcs Insulation No. of cont. Ø in mm 1,0 - 2,0 1,6 - 2,3 1,0 - 2,0 C 16-3 C 16-1 1,6 1,8 - 2,8 C 16-3 C 16-3 C 16-3 1,6 2,5 Stamped contacts on reel for crimp machines 2,5 - 3,5 1,8 - 2,8 Shell size Wire gauge in mm2 AWG Supplied as 2000 pcs (feeding left or right hand side) Contact plating silver 2,5 2,5 - 3,5 gold 14 + PE 1 0,14 - 0,5 single contact 100 VN 02 015 0005 (1) VN 02 015 0005 (2) 17 + PE 1 26 - 20 contacts on reel 200 ZN 02 015 0005 (1) ZN 02 015 0005 (2) 14 + PE 2 right 2000 HN 02 015 0005 (1) HN 02 015 0005 (2) 19 + PE 2 left 14 + PE 1 0,5 - 1,0 single contact 100 VN 02 015 0039 (1) VN 02 015 0039 (2) 17 + PE 1 20 - 18 contacts on reel 200 ZN 02 015 0039 (1) ZN 02 015 0039 (2) 14 + PE 2 right 2000 HN 02 015 0039 (1) HN 02 015 0039 (2) 19 + PE 2 left 6 + PE – 0,14 - 0,5 single contact 100 VN 02 016 0003 (1) VN 02 016 0003 (2) 8 + PE 1 26 - 20 contacts on reel 200 ZN 02 016 0003 (1) ZN 02 016 0003 (2) 12 + PE 2 right 2000 HN 02 016 0003 (1) HN 02 016 0003 (2) 14 + PE 2 left 19 + PE 2 6 + PE – 0,5 - 1,5 single contact 100 VN 02 016 0002 (1) VN 02 016 0002 (2) 8 + PE 1 20 - 16 contacts on reel 200 ZN 02 016 0002 (1) ZN 02 016 0002 (2) 12 + PE 2 right 2000 HN 02 016 0002 (1) HN 02 016 0002 (2) 14 + PE 2 left 6 + PE – 1,5 - 2,5 single contact 100 VN 02 016 0005 (1) VN 02 016 0005 (2) 8 + PE 1 16 - 14 contacts on reel 200 ZN 02 016 0005 (1) ZN 02 016 0005 (2) 12 + PE 2 right 2000 HN 02 016 0005 (1) HN 02 016 0005 (2) 14 + PE 2 left 14 + PE 1 0,5 - 1,5 single contact 100 VN 02 025 0001 (101) VN 02 025 0001 (102) 12 + PE 2 20 - 16 contacts on reel 200 ZN 02 025 0001 (1) ZN 02 025 0001 (2) 14 + PE 2 2000 HN 02 025 0001 (1) HN 02 025 0001 (2) right TN 02 015 0005 (1) TN 02 015 0005 (2) TN 02 015 0039 (1) TN 02 015 0039 (2) TN 02 016 0003 (1) TN 02 016 0003 (2) TN 02 016 0002 (1) TN 02 016 0002 (2) TN 02 016 0005 (1) TN 02 016 0005 (2) left C 16-3 Part No. pcs. TN 02 025 0001 (1) TN 02 025 0001 (2) 14 + PE 1 1,5 - 2,5 single contact 100 VN 02 025 0010 (101) VN 02 025 0010 (102) 12 + PE 2 16 - 14 contacts on reel 200 ZN 02 025 0010 (1) ZN 02 025 0010 (2) 14 + PE 2 2000 HN 02 025 0010 (1) HN 02 025 0010 (2) right left TN 02 025 0010 (1) TN 02 025 0010 (2) Single contact in plasticbag stamped contact on red – HN = feeding right side / TN = feeding left side 34 Amphenol Part No. system for crimp contacts VN __ 1) 1) supplied as: 01 _ _ (1) _ 0001 _ 016 5) 4) 2) 3) VN = single contact 100 pcs. ZN = contacts on reel 100, 200 or 400 contacts HN = Contacts on reel with 2000 contacts for Acrimat FD (contact feeding right hand side) TN = Contacts on reel with 2000 contacts for Acrimat II + III (contact feeding left hand side) 2) Type of contact: 01 = male contact 02 = emale contacts 3) Contact pin dia.: e. g. 016 =^ 1,6 mm 4) Index of version (wire gauge) 5) Plating: Amphenol (1) = silver plated (2) = gold plated (4) = gold plated for high performance 35 Summary of Part No. 36 Part No. Page Part No. Page Part No. Page Part No. Page C016 00U000 000 1 26 C016 10E012 004 2 31 C016 10H014 004 2 30 C016 20C005 100 2 31 C016 00U000 000 2 32 C016 10E012 005 2 31 C016 10H014 005 2 30 C016 20D005 103 2 31 C016 00U000 010 2 32 C016 10E014 002 1 25 C016 10H014 012 5 28 C016 20D005 104 2 31 C016 00U000 020 1 26 C016 10E014 003 1 25 C016 10H014 013 5 28 C016 20E005 103 2 31 C016 00V000 000 1 26 C016 10E014 003 2 31 C016 10H017 002 1 24 C016 20E005 104 2 31 C016 00V000 000 2 32 C016 10E014 004 2 31 C016 10H017 012 5 28 C016 20E005 105 2 31 C016 00V000 010 2 32 C016 10E014 005 2 31 C016 10H017 013 5 28 C016 20F005 104 2 31 C016 00V000 020 1 26 C016 10E017 002 1 25 C016 10H017 801 3 28 C016 20G005 100 2 30 C016 10C008 000 1 26 C016 10E017 003 1 25 C016 10H019 003 2 30 C016 20H005 103 2 30 C016 10C008 000 5 29 C016 10E019 003 2 31 C016 10H019 004 2 30 C016 20H005 104 2 30 C016 10C012 000 2 31 C016 10E019 004 2 31 C016 10H07 003 1 24 C016 20I005 103 2 30 C016 10C014 000 1 26 C016 10E019 005 2 31 C016 10I008 002 1 24 C016 20I005 104 2 30 C016 10C014 000 2 31 C016 10F008 002 1 25 C016 10I008 003 1 24 C016 20I005 105 2 30 C016 10C014 000 5 29 C016 10F008 003 1 25 C016 10I012 003 2 30 C016 20K005 104 2 30 C016 10C017 000 1 26 C016 10F012 004 2 31 C016 10I012 004 2 30 FH 0000-016 26 C016 10C017 000 5 29 C016 10F014 002 1 25 C016 10I012 005 2 30 FH 0002-016 32 C016 10C019 000 2 31 C016 10F014 003 1 25 C016 10I014 002 1 24 HN 01 015 0046 (1) 33 C016 10D008 002 1 25 C016 10F014 004 2 31 C016 10I014 003 1 24 HN 01 015 0046 (2) 33 C016 10D008 003 1 25 C016 10F017 002 1 25 C016 10I014 003 2 30 HN 01 015 0047 (1) 33 C016 10D008 012 5 28 C016 10F017 003 1 25 C016 10I014 004 2 30 HN 01 015 0047 (2) 33 C016 10D008 013 5 28 C016 10F019 004 2 31 C016 10I014 005 2 30 HN 01 016 0002 (1) 33 C016 10D008 801 3 28 C016 10G008 000 1 25 C016 10I017 002 1 24 HN 01 016 0002 (2) 33 C016 10D012 003 2 31 C016 10G008 000 5 29 C016 10I017 003 1 24 HN 01 016 0003 (1) 33 C016 10D012 004 2 31 C016 10G012 000 2 30 C016 10I019 003 2 30 HN 01 016 0003 (2) 33 C016 10D014 002 1 25 C016 10G014 000 1 25 C016 10I019 004 2 30 HN 01 016 0004 (1) 33 C016 10D014 801 3 28 C016 10G014 000 2 30 C016 10I019 005 2 30 HN 01 016 0004 (2) 33 C016 10D014 003 1 25 C016 10G014 000 5 29 C016 10K008 002 1 24 HN 01 016 0005 (1) 33 C016 10D014 003 2 31 C016 10G017 000 1 25 C016 10K008 003 1 24 HN 01 016 0005 (2) 33 C016 10D014 004 2 31 C016 10G017 000 5 29 C016 10K012 004 2 30 HN 01 016 0011 (1) 33 C016 10D014 012 5 28 C016 10G019 000 2 30 C016 10K014 002 1 24 HN 01 016 0011 (2) 33 C016 10D014 013 5 28 C016 10H008 002 1 24 C016 10K014 003 1 24 HN 01 025 0001 (1) 33 C016 10D017 002 1 25 C016 10H008 801 3 28 C016 10K014 004 2 30 HN 01 025 0001 (2) 33 C016 10D017 801 3 28 C016 10H008 003 1 24 C016 10K017 002 1 24 HN 01 025 0010 (1) 33 C016 10D017 003 1 25 C016 10H008 012 5 28 C016 10K017 003 1 24 HN 01 025 0010 (2) 33 C016 10D017 012 5 28 C016 10H008 013 5 28 C016 10K019 004 2 30 HN 02 015 0005 (1) 34 C016 10D017 013 5 28 C016 10H012 003 2 30 C016 10N008 000 5 29 HN 02 015 0005 (2) 34 C016 10D019 003 2 31 C016 10H012 004 2 30 C016 10N008 006 1 25 HN 02 015 0039 (1) 34 C016 10D019 004 2 31 C016 10H014 002 1 24 C016 10N014 000 5 29 HN 02 015 0039 (2) 34 C016 10E008 002 1 25 C016 10H014 801 3 28 C016 10N014 006 1 25 HN 02 016 0002 (1) 34 C016 10E008 003 1 25 C016 10H014 003 1 24 C016 10N017 000 5 29 HN 02 016 0002 (2) 34 C016 10E012 003 2 31 C016 10H014 003 2 30 C016 10N017 006 1 25 HN 02 016 0003 (1) 34 Amphenol Summary of Part No. Part No. Page Part No. Page Part No. Page Part No. Page HN 02 016 0003 (2) 34 T 3107 500 13 TN 02 015 0005 (2) 34 VN 02 025 0001 (101) 34 HN 02 016 0005 (1) 34 T 3108 000 12 TN 02 015 0039 (1) 34 VN 02 025 0001 (102) 34 HN 02 016 0005 (2) 34 T 3108 001 12 TN 02 015 0039 (2) 34 VN 02 025 0010 (101) 34 HN 02 025 0001 (1) 34 T 3108 081 12 TN 02 016 0002 (1) 34 VN 02 025 0010 (102) 34 HN 02 025 0001 (2) 34 T 3108 091 12 TN 02 016 0002 (2) 34 ZN 01 015 0046 (1) 33 HN 02 025 0010 (1) 34 T 3108 100 12 TN 02 016 0003 (1) 34 ZN 01 015 0046 (2) 33 HN 02 025 0010 (2) 34 T 3108 101 12 TN 02 016 0003 (2) 34 ZN 01 015 0047 (1) 33 N 16 110 2000 X 16 T 3108 200 12 TN 02 016 0005 (1) 34 ZN 01 015 0047 (2) 33 T 3102 003 7 X 16 T 3109 000 14 TN 02 016 0005 (2) 34 ZN 01 016 0002 (1) 33 T 3102 004 7 X 16 T 3109 001 14 TN 02 025 0001 (1) 34 ZN 01 016 0002 (2) 33 T 3102 005 7 X 16 T 3109 081 14 TN 02 025 0001 (2) 34 ZN 01 016 0003 (1) 33 T 3102 014 7 X 16 T 3109 091 14 TN 02 025 0010 (1) 34 ZN 01 016 0003 (2) 33 T 3102 015 7 X 16 T 3109 100 14 TN 02 025 0010 (2) 34 ZN 01 016 0004 (1) 33 T 3104 000 12 T 3109 101 14 VN 01 015 0046 (1) 33 ZN 01 016 0004 (2) 33 T 3104 001 12 T 3109 200 14 VN 01 015 0046 (2) 33 ZN 01 016 0005 (1) 33 T 3104 081 12 T 3110 000 15 VN 01 015 0047 (1) 33 ZN 01 016 0005 (2) 33 T 3104 091 12 T 3110 010 15 VN 01 015 0047 (2) 33 ZN 01 016 0011 (1) 33 T 3104 100 12 T 3111 000 13 VN 01 016 0002 (1) 33 ZN 01 016 0011 (2) 33 T 3104 101 12 T 6482 200 16 VN 01 016 0002 (2) 33 ZN 01 025 0001 (1) 33 T 3104 200 12 T 6482 201 16 VN 01 016 0003 (1) 33 ZN 01 025 0001 (2) 33 T 3104 501 12 T 6483 200 16 VN 01 016 0003 (2) 33 ZN 01 025 0010 (1) 33 T 3104 581 12 T 6483 201 16 VN 01 016 0004 (1) 33 ZN 01 025 0010 (2) 33 T 3104 591 12 TN 01 015 0046 (1) 33 VN 01 016 0004 (2) 33 ZN 02 015 0005 (1) 34 T 3104 601 12 TN 01 015 0046 (2) 33 VN 01 016 0005 (1) 33 ZN 02 015 0005 (2) 34 T 3104 701 12 TN 01 015 0047 (1) 33 VN 01 016 0005 (2) 33 ZN 02 015 0039 (1) 34 T 3105 000 14 TN 01 015 0047 (2) 33 VN 01 016 0011 (1) 33 ZN 02 015 0039 (2) 34 T 3105 001 14 TN 01 016 0002 (1) 33 VN 01 016 0011 (2) 33 ZN 02 016 0002 (1) 34 T 3105 081 14 TN 01 016 0002 (2) 33 VN 01 025 0001 (101) 33 ZN 02 016 0002 (2) 34 T 3105 091 14 TN 01 016 0003 (1) 33 VN 01 025 0001 (102) 33 ZN 02 016 0003 (1) 34 T 3105 100 14 TN 01 016 0003 (2) 33 VN 01 025 0010 (101) 33 ZN 02 016 0003 (2) 34 T 3105 101 14 TN 01 016 0004 (1) 33 VN 01 025 0010 (102) 33 ZN 02 016 0005 (1) 34 T 3105 200 14 TN 01 016 0004 (2) 33 VN 02 015 0005 (1) 34 ZN 02 016 0005 (2) 34 T 3105 501 14 TN 01 016 0005 (1) 33 VN 02 015 0005 (2) 34 ZN 02 025 0001 (1) 34 T 3105 581 14 TN 01 016 0005 (2) 33 VN 02 015 0039 (1) 34 ZN 02 025 0001 (2) 34 T 3105 591 14 TN 01 016 0011 (1) 33 VN 02 015 0039 (2) 34 ZN 02 025 0010 (1) 34 T 3105 601 14 TN 01 016 0011 (2) 33 VN 02 016 0002 (1) 34 ZN 02 025 0010 (2) 34 T 3105 701 14 TN 01 025 0001 (1) 33 VN 02 016 0002 (2) 34 T 3106 000 15 TN 01 025 0001 (2) 33 VN 02 016 0003 (1) 34 T 3106 010 15 TN 01 025 0010 (1) 33 VN 02 016 0003 (2) 34 T 3106 500 15 TN 01 025 0010 (2) 33 VN 02 016 0005 (1) 34 T 3107 000 13 TN 02 015 0005 (1) 34 VN 02 016 0005 (2) 34 Amphenol 37 International Argentina Amphenol Argentina Av. Callao 930 2nd Floor Office B “Plaza“ C 1023 AAP Buenos Aires Phone +54 / 11 / 48 15 68 86 Fax +54 / 11 / 48 14 57 79 Australia Amphenol Australia Ltd. 2 Fiveways Blvd Keysborough Victoria 31 73 Phone +61 / 3 / 8796 / 8888 Fax +61 / 3 / 8796 / 8801 Brasilia Amphenol do Brasil Ltda. Rua Diogo Moreira 132, 20th Floor CEP 05423-010 Sao Paulo SP Phone +55 / 11 / 3815.1003 Fax +55 / 11 / 3815.1629 France Amphenol Socapex S.A.S. Mil-Aero Business Unit 948, Promenade de l’Arve B.P. 29 74311 Thyez Cedex Phone +33 / 4 / 5089-2800 Fax +33 / 4 / 5096-1941 ATE 2020 C 0404 2.000 Printed on chlorin-free bleached paper, specifications may be changed without notice. Copyright 04/04 by Amphenol-Tuchel Electronics GmbH, Germany Great Britain Pyle-National A division of Amphenol Ltd. Unit D1, Crossgate Drive Queens Drive Industrial Estate Nottingham, NG2 1LW Phone: +44 / 115 / 986 6200 Fax +44 / 115 / 986 6212 Hongkong Amphenol East Asia Limited 26/F Railway Plaza 39 Chatham Road South Tsimshatsui, Kowloon Phone +8 52 / 26 99 / 26 63 Fax +8 52 / 26 88 / 09 74 India Amphetronix Limited Plot No. 105 Bhosari Industrial Area Pune - 411 026 Phone +91 / 20 / 27121418 Fax +91 / 20 / 2712 05 81 Italy Amphenol Italia S.p.A. Via Barbaiana n. 5 l-20020 Lainate (MI) Phone +39 / 2 / 93 254.1 Fax +39 / 2 / 93 254.445 Sweden Amphenol Scandinavia Johanneslundsvägen 2 194 61 Upplands Väsby Phone +46 / 8 / 59 41 04 40 Fax +46 / 8 / 59 03 38 00 Japan Amphenol Japan, K.K. 2-3-27, Kudan Minami Chiyoda-Ku Tokyo 102 Phone +81 / 3 / 32 63 / 56 11 Fax +81 / 3 / 52 76 / 70 59 Spain Amphenol Ibérica C/Comunidad de Madrid, 35-bis oficina N° 55 “Edificio Burgosol“ E-28230 las Rozas Madrid Phone +34 / 91 64 07 30 2 Fax +34 / 62 90 54 62 9 Korea Amphenol DaeShin Limited #802 Joong-Dong 1131-5 Wonmi-Ku Bucheon-City Kyunggi-Do Korea 420-020 Phone +82 / 2 / 785 / 1588 Fax +82 / 2 / 589 / 1514 South Africa Amphenol International Ltd Chislehurston 30 Impala Road Chislehurston Sandton, 2146 Phone +27 / 11 / 7 83 95 17 Fax +27 / 11 / 7 83 95 19 Mexico Amphenol Mexico Prolongacion Reforma 61 - 6 B2 Col. Paseo de las Lomas C.P. 01330 Mexico D.F. Phone +52 / 55 / 5258.9984 Fax +52 / 55 / 5081.6890 Netherlands Amphenol Benelux b.v. Hoofdveste 19 3992 AK Houten Phone +31 / 30 / 6 35 80 00 Fax +31 / 30 / 6 37 78 99 Peoples Republic of China Amphenol-Tuchel Electronics GmbH China Branch 210-1 Taishan Road Changzhou 213 022 Phone +86 / 05 19 / 5 11 03 01 Fax +86 / 05 19 / 5 11 02 99 Singapore Amphenol East Asia Limited Asia Pacific Sales Operation Singapore Branch 300 Beach Road #25-07 The Concourse Singapore 199555 Phone +27 / 11 / 305-95 74 Fax +27 / 11 / 305-95 76 Taiwan Amphenol East Asia Ltd. Taiwan Branch (H.K.) 116 Zhong Shan Road Lane 956 Taoyuan City Taiwan R.O.C. 330 Phone +886 / 3 / 370 / 7855 Fax +886 / 3 / 360 7259 Turkey Amphenol Turkiye Ayazaga Mah. Meydan Sk. No. 28 Beybi Giz Plaza, Kat. 26 34396 Maslak / Istanbul Phone +90 / 0212 / 335 25 01 Fax +90 / 0212 / 335 25 00 USA Amphenol-Tuchel Electronics Representative Office 6900 Haggerty Road Suite 200 Canton, Michigan 48187 Phone +1 / 734 / 451 6400 Fax +1 / 734 / 451 7197 Amphenol Corporation Corporate Headquarters 358 Hall Avenue Wallingford, CT 06492 Phone +1 / 2 03 / 2 65 / 89 00 Fax +1 / 2 03 / 2 65 / 86 28 Your engineering sales representives: Amphenol Amphenol-Tuchel Electronics GmbH August-Haeusser- Str. 10 . D-74080 Heilbronn . Germany . Phone +49 (0) 71 31/ 9 29-0 . Fax +49 (0) 71 31/ 9 29- 486 · www.amphenol.info
C016 00V000 000 1 价格&库存

很抱歉,暂时无法提供与“C016 00V000 000 1”相匹配的价格&库存,您可以联系我们找货

免费人工找货